Reputation Level:  | Elecro heater problem? Hi, I have just installed a 3kw elecro evo 900 heater. I have tried to get the set point to 14c but the top little dot will not stay on. The water temp is 11c so the heat on light should be constantly on right? But it just comes on for maybe 10 seconds every minute. Is this normal?
Thanks
James |
| | | Sponsored Links - Support the forum by using these links! | | |
03-12-2011, 06:19 AM
|
#2 (permalink)
| | Moderator
Join Date: Jan 2009 Location: Essex
Posts: 557
Reputation Level:  | try taking the temp setting up to 16c see if it stays on all the time....
they tend to have a couple of degree tolerance but shouldnt be as much as your saying.
__________________
A.T.B. |
| |
03-12-2011, 04:58 PM
|
#3 (permalink)
| | Extreme Koi Member
Join Date: Jun 2011 Location: earl shilton
Posts: 194
Reputation Level:  | hi i have one of these heaters but mine dont swing that much mine is more or less spot on is it digital or manual ? there support service is really good there number is 01438 749474and they give free tech advice
Last edited by gaz 69 : 03-12-2011 at 05:00 PM.
|
| |
03-12-2011, 10:08 PM
|
#4 (permalink)
| | Extreme Koi Member
Join Date: Sep 2011
Posts: 70
Reputation Level:  | It's digital I timed it tonight and it heats for 37 seconds and goes to standby for 1 min 37 seconds. Is this normal working procedure or should it heat constantly until the set temperature is reached? It is slowly increasing the temp, only had it running for a day and it's gone up 1c. |
| |
04-12-2011, 04:48 PM
|
#5 (permalink)
| | Extreme Koi Member
Join Date: Jun 2011 Location: earl shilton
Posts: 194
Reputation Level:  | hi JM mine turns on until it get it to the temp its supposed to be then switches of and dont come back on untill water drops in temp so i think something is not right i would ring them tomorrow if theres no one there to talk they take your number and they do yes they do ring you back |
| |
04-12-2011, 05:22 PM
|
#6 (permalink)
| | Moderator
Join Date: Jan 2011 Location: Isle of wight
Posts: 1,081
Reputation Level:  | Quote:
Originally Posted by JM350Z Hi, I have just installed a 3kw elecro evo 900 heater. I have tried to get the set point to 14c but the top little dot will not stay on. The water temp is 11c so the heat on light should be constantly on right? But it just comes on for maybe 10 seconds every minute. Is this normal?
Thanks
James | Hi Jm
I think the problem might be the flow you need to have a good flow through heater or the heater will switch off.
Shevy
__________________ Please click on the banner to visit the site. 1x 5700 Gallon pond
1x 4 Bay filter
1x Large Vortex
2x Box filters
3x UV 80,55,15,
1x 6kw Heater
2x Skimmers
1x protein skimmer
2x Airaters
1x Sieve
68 Koi
5 Goldfish
4 Pumps 2x15000 1x 8000 1x 6000
1 Veggie filter
1 Sand Filter (24") and Pump |
| |
04-12-2011, 07:27 PM
|
#7 (permalink)
| | Extreme Koi Member
Join Date: Sep 2011
Posts: 70
Reputation Level:  | I have it running after my fish mate 45000 pressurised filter which is fed by a superfish 12000 at a head of 2 meters. I thought the flow would be more than enough? |
| |
04-12-2011, 08:21 PM
|
#8 (permalink)
| | Extreme Koi Member
Join Date: Jun 2011 Location: earl shilton
Posts: 194
Reputation Level:  | yes min flow rate is a 1000ltrs that what it says on my booklet |
| |
04-12-2011, 08:32 PM
|
#9 (permalink)
| | Extreme Koi Member
Join Date: Sep 2011
Posts: 70
Reputation Level:  | Could having too much flow be a problem? It says max 7000. I think I will just call them tomorrow |
| |
04-12-2011, 08:43 PM
|
#10 (permalink)
| | Extreme Koi Member
Join Date: Sep 2011
Posts: 70
Reputation Level:  | It's not the flow because I just went outside and reduced the by closing the inline valve quite a bit and nothing changed, heats for 37 seconds then standby for nearly 2 minutes! So annoying |
| |  | | |
Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | | | | Thread Tools | | | | Display Modes | Linear Mode |
Posting Rules
| You may not post new threads You may not post replies You may not post attachments You may not edit your posts HTML code is Off | | |
Similar Threads | | Thread | Thread Starter | Forum | Replies | Last Post | | Heater position? | Davej | DIY Tips and Tricks - DIY Projects | 10 | 25-04-2012 08:28 AM | | Wanted; 2 kw pond heater Doncaster Area | chagboy | Koi and Pond Equipment Wanted | 1 | 17-02-2012 02:43 PM | | HEATER | gaz 69 | General Koi Carp Chat | 7 | 16-11-2011 04:26 PM | | heater | terrydog | General Koi Carp Chat | 5 | 14-11-2011 04:06 PM | | » Competitions | | » Online Users: 42 | | 15 members and 27 guests | | archie33, colinkoi, Cstewart, Doghouse Riley, faz201283, fishing4england, fishysteve, Fish_Man, Gregg, jaykoi, MalNorwich, pauledwards, terrydog, Zoe4eva, ^Dylan | | Most users ever online was 205, 07-01-2012 at 09:40 AM. | » Recent Threads | | | | | | | | | | | | | | | | | | | | | » May 2012 | | S | M | T | W | T | F | S | | 29 | 30 |
1
|
2
|
3
|
4
|
5
| |
6
|
7
|
8
|
9
|
10
|
11
|
12
| |
13
|
14
|
15
|
16
|
17
|
18
|
19
| |
20
|
21
|
22
|
23
|
24
|
25
|
26
| |
27
|
28
|
29
|
30
|
31
| 1 | 2 | |